Name:                                                  100 Amp Cut Out
Rated Voltage (kV):                                     11
Impulse Voltage (kV):                                    150
Power-frequency Withstand Voltage(kV):       65
Creepage Distance (mm):                             540
Rated Current (A):                                   100,200
High Light:                                      Ceramic Drop Out Fuse Cutout

                                                         11KV Drop Out Fuse Cutout
                                                         Porcelain Expulsion Drop Out Fuse
 
 
Availability:
Quantity:
  • RW12-11/100

  • SASUN

  • 8535100000-3


The 11kV 100A porcelain cutout fuse (with interrupter) is an overcurrent protection device for medium voltage distribution lines (6-11kV), integrating porcelain insulator and high-efficiency interrupter to achieve fast breaking (≤10ms), visible breakpoint isolation and long-life maintenance. Key benefits include:

High arc control: The arc extinguisher is designed with a breaking capacity of up to 16kA, which is suitable for frequent operation scenarios (such as industrial power distribution, photovoltaic/wind power collector lines).
Anti-fouling and flashover performance: the creepage distance of the porcelain umbrella skirt ≥ 450mm (suitable for grade IV dirt areas).
Mechanical reliability: porcelain bending strength ≥ 10kN, contact pressure ≥ 250N, mechanical life ≥ 2000 times.
Typical Applications:

Primary side protection of distribution transformers
Overhead line segment fault isolation
Incoming protection of ring main unit in industrial plant
Lightning protection cooperation in high thunderstorm areas


依据IEC 60282-1、GB/T 15166.2)
parameterTechnical Indicators
Rated voltage11kV (maximum applicable voltage 12.7kV)
Current rating100A (continuous current-carrying, temperature rise≤60K)
Breaking capacity16kA (symmetrical RMS, 0.2s)
Arc extinguishing time≤ 10ms (at 12kA fault current)
Power Frequency Withstand Voltage (Dry/Wet)Dry state: 38kV/1min, wet state: 28kV/1min
Withstand lightning impulse voltage95kV (peak, 10 times each of positive and negative polarity)
Creepage distance≥450mm (anti-fouling umbrella skirt design)
Interrupter materialArc-resistant ceramic + copper-tungsten alloy grid (resistant to 3000°C high temperature)
Mechanical life
≥ 2000 splitting and closing operations
weight4.2-5.0kg (including interrupter)


Application scenarios
Industrial power distribution: high-voltage bus protection for motor groups
New energy station: overcurrent protection on the high-voltage side of the box transformer
Urban power grid: fault isolation of cable branch box
Mine power supply: short circuit protection for mobile substation



Previous: 
Next: 
Sasun International Electric Co., Ltd, was established in 2001, As a professional manufacturer & exporter on high voltage overhead line product in China

QUICK LINKS

PRODUCTS

CONTACT US

Inquire
Copyright © 2024 Sasun International Electric Co., Ltd. All Rights Reserved. Sitemap