Usage: | High Voltage |
Breaking Capacity: | High |
Safety Standards: | IEC |
Standard: | GBJ, JB,IEC |
Rated Voltage: | 11-15KV |
Rated Current: | 100A,200A |
Mechanical Life: | 10000 |
Port: | NINGBO |
High Light: | 300 amp cut out |
cut out fuse holder |
Availability: | |
---|---|
Quantity: | |
PD-12/100
SASUN
8535100000-5
The 15kV 100A polymer cutout fuse replaces the traditional porcelain insulator with silicone rubber composite insulating material, which has the characteristics of light weight (weight reduction by 50%), impact resistance, anti-pollution flashover and long life (≥ 30 years), suitable for:
Harsh environments: high humidity, strong ultraviolet rays, coastal salt spray areas
Frequent operation scenarios: photovoltaic/wind power collector lines, urban ring main unit
High reliability requirements: no need for regular cleaning, maintenance-free design
parameter | Technical Indicators |
Rated voltage | 15kV (up to 17.5kV) |
Current rating | 100A (continuous current-carrying, temperature rise≤55K) |
Breaking capacity | 16kA (symmetrical RMS, 0.2s) |
Withstand lightning impulse voltage | 110kV (peak, 10 times each of positive and negative polarity) |
Creepage distance | ≥540mm (silicone rubber umbrella skirt, anti-fouling flash design) |
工频耐压 | 45kV/1min (dry), 35kV/1min (wet) |
Mechanical life | ≥5000 times (silver plated contacts, wear rate ≤ 0.1μm/time) |
Ingress protection | IP68 (fully sealed structure, can be immersed in water for 1m/1h) |
UV resistance rating | UV-C (Resistant to ≥ 15 years of strong sunlight) |
weight | 2.8-3.5kg (only 40% of porcelain fuse) |
The 15kV 100A polymer cutout fuse replaces the traditional porcelain insulator with silicone rubber composite insulating material, which has the characteristics of light weight (weight reduction by 50%), impact resistance, anti-pollution flashover and long life (≥ 30 years), suitable for:
Harsh environments: high humidity, strong ultraviolet rays, coastal salt spray areas
Frequent operation scenarios: photovoltaic/wind power collector lines, urban ring main unit
High reliability requirements: no need for regular cleaning, maintenance-free design
parameter | Technical Indicators |
Rated voltage | 15kV (up to 17.5kV) |
Current rating | 100A (continuous current-carrying, temperature rise≤55K) |
Breaking capacity | 16kA (symmetrical RMS, 0.2s) |
Withstand lightning impulse voltage | 110kV (peak, 10 times each of positive and negative polarity) |
Creepage distance | ≥540mm (silicone rubber umbrella skirt, anti-fouling flash design) |
工频耐压 | 45kV/1min (dry), 35kV/1min (wet) |
Mechanical life | ≥5000 times (silver plated contacts, wear rate ≤ 0.1μm/time) |
Ingress protection | IP68 (fully sealed structure, can be immersed in water for 1m/1h) |
UV resistance rating | UV-C (Resistant to ≥ 15 years of strong sunlight) |
weight | 2.8-3.5kg (only 40% of porcelain fuse) |